After doing all the above, reassemble the heater and relight the pilot. It also implies RAM loaded over 90% and the battery life reduced to 15% or less. This makes the pilot flame small and unsustainable. You will need to know how to properly light your electric ignition water heater. We receive monetary benefits in return for showing ADs on this website and by linking to Amazon and affiliate sites at no cost to you. Reconnect gas supply line. If your electronic ignition water heater, will not light, then it could be a loose wire, the ignition may not be getting the correct voltage, or you may just need to try lighting it more than once. Or from your water heaters front, the water can leak. If the issue is related to only the pilot and igniter, simply cleaning and replacing the defective parts can resolve the problem. > Bad outer poor thermostat knob/gas control valve set to on position. How do I know if my water heater thermostat is bad? Any time you work on a hot water heater, you need to make sure that it is unplugged, and that the gas is turned to the off position. When you click on the igniter, there should be a tiny spark happening inside of the pilot. She grew up surrounded by constant home improvement projects and owes most of what she knows to helping her dad renovate her childhood home. Blocked vents or insufficient air supply. Start with the easiest thing first, and work your way down the list. This information is provided as our informed opinion and does not constitute actual advice from a licensed professional. After following this well-proven guide, hopefully, you will not face single trouble while resolving this issue. It should be firmly inserted into the white connector. Once the pilot light is on, continue pressing down on the pilot switch for a minute to allow the flame to heat up the thermocouple. You will need to wait a few minutes, in between lighting it. When the pilot light is on, turn the gas control knob to the desired temperature settings. Repair the damage to stop beeping. If the igniter wires come loose from their connector, the controller will receive no signal for ignition. But when it reads below400 millivolts, be sure the thermopile is faulty, and it needs replacement. Here are the Honeywell water heater issues explained with their easy solutions: Note: Also read to know how to fix Honeywell water heater sensor failure. 1 Additionally, these devices are fueled with flammable natural gas. When troubleshooting your hot water heater, check to ensure that the correct voltage is reaching your gas valve. Jessica considers herself a home improvement and design enthusiast. If its a Honeywell water heater, follow the steps I mentioned to make the replacement with ease. A faulty igniter will fail to glow even after receiving an adequate amount of voltage. Then try again to relight the pilot. Warning. Heater Igniter Not Sparking 3. When this component gets damaged by corrosion or bent, it wont function anymore. Move the brush back and forth and clean the base area properly. > Replace lousy thermostat, & faulty gas control valve turned off the thermostat/control valve. Remove the front access panel of your water heater. Check the T&P valve and verify whether it is in good working condition or not. 5 Flashes = Sensor Failure. Your heaters burner fails to ignite mainly for the following factors: For fixing the above difficulties, the easy resolving ways are: Honeywell water heater overheatingis one of the potentially dangerous issues with your gas water heater. Use your multimeter, to test how much voltage is going to the igniter. Remove the two connectors of red and white wires from the gas control valve. You may have to dim the room lights in order to see . After resolving the pilot issue and there is still no blinking on the status light, a bad igniter or malfunctions from the igniter is the second suspect. I'm a writer that is passionate about home improvements, remodeling, and renovating. Then, clean out the flame arrestor using a household brush. The knob can get stuck in the On/Off/Pilot position. Now carefully detach each of the electrical connectors to the gas control valve. When this happens, your burners wont ignite and your homes water will be freezing cold. Honeywell Water Heater Troubleshooting [11+ Easy Fixes] 1. Learn more, Facebook II Twitter II Pinterest II Linkedin. Afterward, use a screwdriver to remove the plastic face of the control valve. Also, check the thermostat to see if the temperature is correctly set or not. You should not take on any project like this unless you know exactly what you are doing. Make sure that the power of the water heater is turned on. If it doesnt work, you need to replace the corresponding defective part. I enjoy learning new skills and techniques and sharing them with others. If that doesnt prove well, ensure your thermostat is working properly by checking for continuity between its terminals. To determine if the igniter is defective, first make sure the igniter is getting voltage. It must measure at least 19.5VAC with the igniter powered. The other responsible factors of it are: When your water heaters 1 or 2 parts stop working, you will experience your Honeywell water heater with no pilot light or weak pilot light. If your heaters status light wont blink, turn off the gas valve and release the gas control knob. Look through the igniter viewpoint and inspect whether it sparks or not. What are the symptoms of a broken water heater? Your hot water heater may not be sparking due to a defective igniter, electrode or thermocouple. If you have been having trouble with your hot water heater not igniting, then there could be several issues. Faulty gas control valve electrical connection. The recommended thermostat temperature is 120F. To prevent the water heater from leaking, ensure that the flue pipe is venting the combustion gases properly. If your hot water heater suddenly stops working, chances are a bad thermocouple has shut off the gas to the pilot light. Or reset your water heater. The heater overheating can result in a burn or scald in the household. All Right Reserved by HeaterFixLab. What will happen if the water heater gets a high-temperature shutdown? Check the thermostat and if it is defective, replace it with the new one. All Right Reserved by FIREPLACEHUBS. Fortunately, I will put you through the grind to resolve those problems I mentioned. Check to make sure the thermocouple connection to the control valve is tight. To do this, turn the water temperature dial to Low and the On/Off/Pilot knob to Pilot. The igniter itself when out of the control panel sparks fine but when connected it does not spark at all. Easy things, you will be able to work on yourself. You will see two black connectorson the gas control valve. Now relight the pilot following the below section. Any of these can be the reason behind the issue. You will have to unscrew the thermocouple, from the control valve. When this happens, your burners wont ignite, and your homes water will be freezing cold. You can reset your Honeywell Water Heater in some simple ways. Whether the unit be underpowered or there is a bad thermocouple, lets take a look at what you can do when an electronic ignition water heater wont light. If the power to the water heater is not working, then either the circuit breaker or fuse may need to be replaced. Change the defective elements of the system to prevent this problem. Repair the damaged part as soon as possible. So, lets start. Sediment build-up at your water tank bottom leads to premature rusting. Replace the bad thermopile with the help of the technician. Another reason for water heater leaks is the tank not being properly sealed. Also, there have some common reasons that can cause your heater to beep: The water heater keeps turning off is a common phenomenon for water heater owners. Use a screwdriver to unscrew the nuts that hold the manifold door in place. The status light on the gas control valve will not blink if there is an interruption in the gas supply to your water heater. The water heaters safety devices are FV (Flammable Vapor) sensors. If you still can't see a spark, turn the gas control knob OFF, turn the gas supply valve . When your Honeywell heater stops heating, you should check the pilot light first. Then, install it and push it into its place. Some water heaters use an igniter to ignite the gas. Interruption In The Gas Supply 4. But they usually have a manual adjustment knob on the front. When done, connect the outer door and check the status light. Improper installation of the spark rod and the pilot head. If the heater pilot light keeps going out, be sure there isa faulty, misaligned, dirty, or damaged thermocouple responsible for this. Fix any leaks found in step 12. If a flame isnt detected, the ignition process will stall and your burner will not light. > Faulty thermostat knob, or gas control valve. Wait for a while and look for any corrosion on the electrical connection. Lets start: The Honeywell heater users often complain about a major problem: the Honeywell water heater keeps turning off or wont stay lit. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. The spark is small, and the igniter is deep inside the base of the water heater. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Next, remove a screw from the bottom of the Honeywell Gas Control Valve. link to What Kind Of Paint For Garage Walls? But make sure youre not pulling it. The last issue, after you have determined that there is no easy fix, is that the main control valve could be bad. The consent submitted will only be used for data processing originating from this website. However, the more advanced problems will most likely need a licensed plumber. The problem starts with this element when there has a limited voltage supply. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. If the power still isnt working, try to replace the igniter. The control board will throw a code if there is a problem with the voltage. One possibility is that the electrical wiring to the igniter is damaged. Today were going to talk about ways you can prevent the pilot light from going out for good and what you should do if it does go out. Ensure each of the heating elements is blockage free. For instance: Follow the below instruction to resolve the above igniter issues: First up, you have to check the wiring connection of the igniter. Inspect the igniter, for any bad wiring, and if you find any, you may need to resolder the wire or have a professional reattach them for you. Dont over-tighten it, and make sure the valve is completely closed. Well walk you through how to troubleshoot the issue of your water heater igniter not sparking, and educate you on possible solutions. Then, click on the igniter multiple times and look for a spark. Stick to the following steps to learn how to clean igniter on a water heater: If cleaning the thermopile doesnt bring any luck, I bet the igniter itself is the culprit. Save my name, email, and website in this browser for the next time I comment. If these are the culprit, you should follow the solutions below to resolve them: So another problem that you may encounter is the Honeywell water heater no status light. How do I know if the gas valve is bad on my water heater? Save my name, email, and website in this browser for the next time I comment. How do you light a hot water heater with an igniter Honeywell? Honeywell Water Heater Pilot Light Wont Light? Whatever the problem, first reset your heater and find if resetting could fix your heater issues or not. > Verify the whiter igniter is firmly inserted into the white or orange connector. Also, check the wiring connection. The reasons behind this difficulty are: Before your too-hot Honeywell water heater creates any major hitch, you need to fix it immediately. The igniter will have multiple wires that go to it. Verify the water pipes are properly insulated and ventilated. The other causes of it are: Your water heater can make different types of noises such as rumbling, banging, crackling, ticking, hissing, screeching, and popping. We and our partners use cookies to Store and/or access information on a device. Try lighting the pilot following the lighting instructions on the water heater and visually confirm the pilot can be lit. But you might be struggling to figure out what kind of paint to use on garage walls. This means, if the power is out, you will not be able to light the hot water heater. Alternatively, if the pilot light goes out right after you light it, you want to reset the door switch, or high-limit reset switch. We and our partners use cookies to Store and/or access information on a device. Just drain the water and do a flush in the tank. If the pilot does not light, the water heater will not heat up. A defective thermostat can be changed by professionals to overcome this problem. How To Stop Wind From Blowing Out Pilot Light (On A Water Heater). Take a pressure gauge and measure the gas pressure. Due to the high temperature, the T&P starts leaking. if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'fireplacehubs_com-netboard-1','ezslot_24',116,'0','0'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-netboard-1-0');A thermal switch is a safety device on a water heater. The only way for you to troubleshoot your main control valve is to rule out all of the other issues on our list of common problems. Dirt or corrosion on the spark electrode usually interferes with the flow of electricity to the pilot light and can cause it not to ignite. Honeywell Water Heater Igniter Not Working [3 Easy Solutions], Honeywell Water Heater Igniter Replacement [A Step-by-Step Procedure]. Anyway, note down some possible reasons behind the interruption in the fuel supply: Follow the below few phases to fix the gas supply issue: As for the first step, check to see if there is air in the gas line. When you hold down the pilot switch on a gas heater and click the igniter button repeatedly, a small spark should ignite the pilot. Should I Turn Off An Electric Water Heater If The Water Is Off? We don't tend to provide any plumbing advice or any advice that should come from a certified professional. But it should not exceed 120F or 49C. If the igniter seems dirty, clean it by using an emery cloth. To get a better look, consider dimming the lights in the room. Turn the thermostat to its lowest possible setting. Press the button firmly. At the same time as youre holding down the pilot switch, press on the piezo igniter. In some instances, you may need to push the knob down in order to turn it from Pilot to OFF. How Long For A Hot Water Heater To Heat After A Reset? > Ensure all the snug electrical connections to the gas control valve. Save my name, email, and website in this browser for the next time I comment. Why does my Honeywell water heater keep shutting off? The electrode should release a spark simply by pressing the piezo igniter. In this case, the only option you have in front of you is to replace the igniter. If it is, simply replace the igniter/flame rod assembly. The root reasons behind Honeywell hot water heater no status light includes: Furthermore, due to tripped thermal switch, lack of combustion air, and defective heater thermopile, owners will face no status light blinking issue on their water heaters. If the igniter is getting voltage, but it doesn't glow, this indicates that the igniter is defective and should be replaced. Now learn all the probable reasons in detail and how to break down the culprits with ease by following the suggested methods. Clean out clogged debris from the vents using a vent cleaning brush and make them blockage-free. Then, look for any broken or burnt-out heating element. Replace the defective one. Most new electric igniter water heaters will have a control board. Finally, you have to reset the tripped thermal switch to get back the element function again. Honeywell Water Heater Leaking 11. The blinking light on a different number of times indicates that theres something up with your water heater and needs to be fixed as soon as possible. Repair the valve issue with the help of a plumber. Thank for your feedback. Honeywell Water Heater Sensor Failure [5 Easy Fixes], Why Duraflame Heater Flame Not Working [Reasons + Solutions], Richmond Tankless Water Heater Troubleshooting [A Complete Guide], Richmond Electric Water Heater Troubleshooting [A Complete Guide], Richmond Gas Water Heater Troubleshooting [A Complete Guide], Richmond Water Heater Blinking Light Codes [Why+ How To Fix], Richmond Water Heater Gas Valve Problems [Why + How To Fix], > LED is not lit, or the thermopile didnt get the normal temperature yet. Ensure the drain valve is unclogged and working fluently. Problem with the thermocouple: Indeed, the white connector shouldnt touch these components. Follow the solutions below and make sure your Honeywell heaters status light is blinking. Consequently, the pilot wont light and the status light will not blink. You have to define the errors depending on the number of blinking. l O flashes - Control off or Pilot out l 1 flash - Normal operation